About our Capabilities
  Engineering
  Manufacturing
  Quality
 
   



 


Liner burst test
• Required by HSE, TUV and CEN.
• Liner is pressurized with water until failure
• Must remain in one piece


Hydraulic burst test

• European designs require minimum burst pressure
  3 x service pressure.
• DOT (USA) designs require minimum burst pressure
  3.33 x service pressure.
• Typical burst pressure:
• 850 bar for 207 bar design.
• 1100 bar for 300 bar design.



Ambient cycle test

• European standards require a minimum of 3,750 cycles minimum to test pressure.
• DOT (USA) requires 10,000 cycles to service and 30 to test pressure.


Environmental Cycle Test

• Required by both US and European standards.
• 5000 cycles to service pressure at 60°C and 95% humidity.
  5000 cycles to service pressure at -50°C.

• 30 cycles to test pressure at room temperature.

• Burst test.



High velocity impact test

• To show behavior if cylinder is punctured when charged.
Fill cylinder to charging pressure.
• Shoot with 7.62-mm bullet from not more than 45 m.
• No fragmentation permitted.




Bonfire test

• Fill two cylinders to charging pressure.
• Fit with a pressure relief. Place in bonfire until
 
completely vented.
• Cylinder shall not rupture during test.
• Burst for information.
• Typical: Cylinder remains intact.
• Burst pressure from 600 to 1,000 bar depending on
  orientation in fire



 